నైరూప్య

Simultaneous Determination of Atorvastatin and Ezetimibe by RP-HPLC in Pure and Pharmaceutical Dosage Form

B. Neelima, P. Ravi Kumar, M. Murali Krishna, V. Hima Bindu and Y. Rajendra Prasad


A simple, precise and rapid RP-HPLC method was developed for the simultaneous determination of atorvastatin and ezetimibe in combined pharmaceutical dosage forms. The method was carried out on a Shim-pack, RP-C18 column using a mixture of acetonitrile : 0.1% v/v orthophosphoric acid and detection was done at 239 nm using external standard method as quantitation. The linearity range of atorvastatin and ezetimibe were 0.1 to 25 =g/mL. The intra-day and inter-day precision were in the range of 0.55-0.91 and 0.62-0.87 for atorvastatin and 0.48-0.53 and 0.67-1.24 for ezetimibe.


ఇండెక్స్ చేయబడింది

  • CASS
  • గూగుల్ స్కాలర్
  • J గేట్ తెరవండి
  • చైనా నేషనల్ నాలెడ్జ్ ఇన్‌ఫ్రాస్ట్రక్చర్ (CNKI)
  • CiteFactor
  • కాస్మోస్ IF
  • మియార్
  • రహస్య శోధన ఇంజిన్ ల్యాబ్‌లు
  • యూరో పబ్
  • యూనివర్శిటీ డి బార్సిలోనా
  • ICMJE

మరిన్ని చూడండి

జర్నల్ హెచ్-ఇండెక్స్

Flyer