నైరూప్య

A Validated RP-HPLC Method for the Assay of Prulifloxacin in Marketed Drug Product using Levofloxacin as an Internal Standard

P. Ravisankar, G. Devala Rao, Ch. Devadasu, G. Sudhakar Saibabu and P. Srinivasa Babu


A simple, accurate, precise, specific isocratic reversed phase-high performance liquid chromatography (RP-HPLC) method has been developed for the quantitative estimation of prulifloxacin in pharmaceutical formulations. RP-HPLC method was developed by using Welchrom C-18 Column (4.6 x 250 mm, 5 μm), Shimadzu LC-20AT prominence liquid chromatograph. The mobile phase used is phosphate buffer (pH-3.2): acetonitrile (60 : 40 v/v) with a flow rate of 1 mL/min. The responses are measured at 285 nm using Shimadzu SPD-20A prominence UV-Vis detector. Levofloxacin is used as internal standard. The retention times of prulifloxacin and levofloxacin are found to be 7.093 and 2.780 min respectively. The method posses linearity in the range of 2-12 μg/mL. The accuracy and reliability of the proposed method was ascertained by evaluating various validation parameters like linearity, precision and specificity according to ICH guidelines. The proposed method provides an accurate and precise quality control tool for routine analysis of prulifloxacin in tablet dosage forms.


నిరాకరణ: ఈ సారాంశం ఆర్టిఫిషియల్ ఇంటెలిజెన్స్ టూల్స్ ఉపయోగించి అనువదించబడింది మరియు ఇంకా సమీక్షించబడలేదు లేదా నిర్ధారించబడలేదు

ఇండెక్స్ చేయబడింది

  • CASS
  • గూగుల్ స్కాలర్
  • J గేట్ తెరవండి
  • చైనా నేషనల్ నాలెడ్జ్ ఇన్‌ఫ్రాస్ట్రక్చర్ (CNKI)
  • CiteFactor
  • కాస్మోస్ IF
  • ఎలక్ట్రానిక్ జర్నల్స్ లైబ్రరీ
  • రీసెర్చ్ జర్నల్ ఇండెక్సింగ్ డైరెక్టరీ (DRJI)
  • రహస్య శోధన ఇంజిన్ ల్యాబ్‌లు
  • ICMJE

మరిన్ని చూడండి

జర్నల్ హెచ్-ఇండెక్స్

Flyer